Specifications 467

If you want to buy Hengstler 467 , as well as order other industrial equipment and spare parts for its repair, please contact FAMAGA .

We have been delivering Hengstler products throughout the UK and anywhere in the world for over 10 years. All equipment and components are provided with appropriate quality certificates, together with a guarantee from the official manufacturer of products Hengstler.

Thanks to the direct deliveries from leading European manufacturers and a minimum trade margin, we offer our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the products we supply and the professionalism of the FAMAGA employees.

To clarify the cost of Hengstler 467 and delivery times, you can fill out a special order form on our website, send a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any city in the UK and any country in the world.

Features 467

HENGSTLER's H-467 safety relay is used wherever a high number of switching actions is required at moderate switching loads. With a max. installation height of 17.1 mm, a high component density can be achieved. H-467 safety relays conform to EN 50205 standard, Application type A, and IEC EN 61810-1.
  • 4 contacts
  • max. 6 A switching & permanent current
  • Drive is monostable as DC
  • Ambient temperature -25 to +80 °C
  • With forcibly guided contacts to EN 50205, application type A
  • CSA and TUV approval
Function / ApplicationSafety relay
Product lineHENGSTLER
Relay family467
Contactsetforcibly guided
According EN 50205Application type A
Ambient temperature [°C]-25 ... +80 °C
Soldering heat resistance [°C]260 °C
Max. soldering time [s]5 s
Pins pre-soldered with Sn 100
Approval
  • TUV
  • CSA
Standards
  • EN 50205
  • IEC 61810-1
Meets the requirementsRoHS
Number of NO contacts2 ... 3
Number of NC contacts1 ... 2
Number of CO contacts0
Dimensions L x W x H [mm]44,9 x 42,7 x 17,1 mm
Housing
  • dustproof (RT II)
  • washtight (RT III)
Shock resistance NO / NC [g]15/15 g
Puls duration (half sinus)11 ms
Vibration resistance NO / NC [g]1,5/1,5 g
Frequency range [Hz]10 - 150 Hz
Operating time NC contact, contact opens [ms] 10 ms
Operating time NO contact, contact closes [ms] 14 ms
Releasing time NO contact, contact opens [ms] 3,5 ms
Releasing time NC contact, contact closes [ms] 4,5 ms
Mechanical service life (without load)10,000,000 switching cycles
Connection typeSolder pins for pcb
Weight [g]55 g
Drive system DC monostable
Nominal coil voltage [V]5 ... 220 V
Coil resistance [Ohm]12 ... 50,000 Ohm
Contact material
  • AgCdO + 0,2 ... 5 µm Au
  • AgSnO + 0,2 ... 5 µm Au
Max. switching current [A]6 A
Max. switching voltage [V]230/240 V
Max. switching capacity [VA]1200 VA
Switching capacity AC-15 at 230 V [Ie in A]1,5 A
Switching capacity DC-13 at 24 V [Ie in A]2 A
Electrical service life (with nominal load)100,000 cycles
Short-circuit capacity 1000 A / AC 230 V [A]6 A
InsulationBasic insulation
Function / ApplicationSafety relay
Product lineHENGSTLER
Relay family467
Contactsetforcibly guided
According EN 50205Application type A
Ambient temperature [°C]-25 ... +80 °C
Soldering heat resistance [°C]260 °C
Max. soldering time [s]5 s
Pins pre-soldered with Sn 100
Approval
  • TUV
  • CSA
Standards
  • EN 50205
  • IEC 61810-1
Meets the requirementsRoHS
Number of NO contacts2 ... 3
Number of NC contacts1 ... 2
Number of CO contacts0
Dimensions L x W x H [mm]44,9 x 42,7 x 17,1 mm
Housing
  • dustproof (RT II)
  • washtight (RT III)
Shock resistance NO / NC [g]15/15 g
Puls duration (half sinus)11 ms
Vibration resistance NO / NC [g]1,5/1,5 g
Frequency range [Hz]10 - 150 Hz
Operating time NC contact, contact opens [ms] 10 ms
Operating time NO contact, contact closes [ms] 14 ms
Releasing time NO contact, contact opens [ms] 3,5 ms
Releasing time NC contact, contact closes [ms] 4,5 ms
Mechanical service life (without load)10,000,000 switching cycles
Connection typeSolder pins for pcb
Weight [g]55 g
Drive system DC monostable
Nominal coil voltage [V]5 ... 220 V
Coil resistance [Ohm]12 ... 50,000 Ohm
Contact material
  • AgCdO + 0,2 ... 5 µm Au
  • AgSnO + 0,2 ... 5 µm Au
Max. switching current [A]6 A
Max. switching voltage [V]230/240 V
Max. switching capacity [VA]1200 VA
Switching capacity AC-15 at 230 V [Ie in A]1,5 A
Switching capacity DC-13 at 24 V [Ie in A]2 A
Electrical service life (with nominal load)100,000 cycles
Short-circuit capacity 1000 A / AC 230 V [A]6 A
InsulationBasic insulation