We are not the manufacturer, authorised distributor or authorised representative of the Hengstler brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to buy Hengstler 462 , as well as order other industrial equipment and constituent parts for its mend, please contact FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Iceland, Zimbabwe, Saudi Arabia, Latvia, Côte d\'Ivoire, Norway, Kiribati, Liberia, Croatia, Rwanda, Bahrain, Honduras, Belgium, Colombia, Morocco, Bosnia and Herzegovina, Armenia, Sri Lanka, South Sudan, Slovenia, Lebanon, Moldova, Niger, Antigua and Barbuda, Serbia, Cambodia, Liechtenstein, Luxembourg, Congo, Kenya, Philippines, Lesotho, Bangladesh, Oman, Namibia, Burkina Faso, Sudan, Albania, Tonga, Suriname, Spain, Monaco, Peru, Egypt.
We have been delivering Hengstler elements all around the UK and anywhere in the world for over 11 years. All equipment and replacements are provided with appropriate quality certificates, together with a guarantee from the official creator of products Hengstler.
Thanks to the direct deliveries from major European manufacturers and a minimum trade margin, we propose our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the elements we supply and the professionalism of the FAMAGA employees.
To clarify the expense of Hengstler 462 and shipment time, you can complete a special inquiry form on our website, dispatch a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any urban place in the UK and any country in the world.
Function / Application | Safety relay |
Product line | HENGSTLER |
Relay family | 462 |
Contactset | forcibly guided |
According EN 50205 | Application type A |
Ambient temperature [°C] | -25 ... +80 °C |
Soldering heat resistance [°C] | 260 °C |
Max. soldering time [s] | 5 s |
Pins pre-soldered with | Sn 100 |
Approval |
|
Standards |
|
Meets the requirements |
|
Number of NO contacts | 2 ... 4 |
Number of NC contacts | 1 ... 3 |
Number of CO contacts | 0 |
Size | 1 / 2 |
Dimensions L x W x H [mm] |
|
Housing | dustproof (RT II) |
Shock resistance NO / NC [g] | 10/10 g |
Puls duration (half sinus) | 16 ms |
Vibration resistance NO / NC [g] | 10/10 g |
Frequency range [Hz] | 10 - 55 Hz |
Operating time NC contact, contact opens [ms] | 17 ms |
Operating time NO contact, contact closes [ms] | 23 ms |
Releasing time NO contact, contact opens [ms] | 5 ms |
Releasing time NC contact, contact closes [ms] | 7 ms |
Mechanical service life (without load) | 10,000,000 switching cycles |
Connection type |
|
Fixing type | Contact: Solder pins |
Drive system |
|
Nominal coil voltage [V] |
|
Nominal coil current [A] | 5 ... 230 V |
Resistance tolerance [%] | 10 ... 73,700 Ohm |
Max. switching current [A] |
|
Continuous current Ith2 at same time over 2 contacts [A] | 10 A |
Max. switching capacity [VA] | 230/240 V |
Max. switching capacity [W] | 2000 VA |
Switching capacity DC-13 at 24 V [Ie in A] | 4 A |
Contact gap about open contact | 2 A |
Short-circuit capacity 1000 A / AC 230 V [A] | 100,000 cycles |
Insulation | 10 A |
Function / Application | Safety relay |
Product line | HENGSTLER |
Relay family | 462 |
Contactset | forcibly guided |
According EN 50205 | Application type A |
Ambient temperature [°C] | -25 ... +80 °C |
Soldering heat resistance [°C] | 260 °C |
Max. soldering time [s] | 5 s |
Pins pre-soldered with | Sn 100 |
Approval |
|
Standards |
|
Meets the requirements |
|
Number of NO contacts | 2 ... 4 |
Number of NC contacts | 1 ... 3 |
Number of CO contacts | 0 |
Size | 1 / 2 |
Dimensions L x W x H [mm] |
|
Housing | dustproof (RT II) |
Shock resistance NO / NC [g] | 10/10 g |
Puls duration (half sinus) | 16 ms |
Vibration resistance NO / NC [g] | 10/10 g |
Frequency range [Hz] | 10 - 55 Hz |
Operating time NC contact, contact opens [ms] | 17 ms |
Operating time NO contact, contact closes [ms] | 23 ms |
Releasing time NO contact, contact opens [ms] | 5 ms |
Releasing time NC contact, contact closes [ms] | 7 ms |
Mechanical service life (without load) | 10,000,000 switching cycles |
Connection type |
|
Fixing type | Contact: Solder pins |
Drive system |
|
Nominal coil voltage [V] |
|
Nominal coil current [A] | 5 ... 230 V |
Resistance tolerance [%] | 10 ... 73,700 Ohm |
Max. switching current [A] |
|
Continuous current Ith2 at same time over 2 contacts [A] | 10 A |
Max. switching capacity [VA] | 230/240 V |
Max. switching capacity [W] | 2000 VA |
Switching capacity DC-13 at 24 V [Ie in A] | 4 A |
Contact gap about open contact | 2 A |
Short-circuit capacity 1000 A / AC 230 V [A] | 100,000 cycles |
Insulation | 10 A |