462 Hengstler
 462 Hengstler

We are not the manufacturer, authorised distributor or authorised representative of the Hengstler brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.

Hengstler 462

Manufacturer

Hengstler

Country

USA

Name

462

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications 462

If you want to buy Hengstler 462 , as well as order other industrial equipment and constituent parts for its mend, please contact FAMAGA .

We have been delivering Hengstler elements all around the UK and anywhere in the world for over 11 years. All equipment and replacements are provided with appropriate quality certificates, together with a guarantee from the official creator of products Hengstler.

Thanks to the direct deliveries from major European manufacturers and a minimum trade margin, we propose our customers the most affordable prices for all products presented in our catalogue. If necessary, our qualified specialists will help you select industrial equipment that will fully meet the requirements of the production process. More than 4,000 customers have already appreciated the high quality of the elements we supply and the professionalism of the FAMAGA employees.

To clarify the expense of Hengstler 462 and shipment time, you can complete a special inquiry form on our website, dispatch a list of necessary equipment by E-mail or call to the mentioned phone numbers. We will be able to make the best commercial offer for you and provide optimal delivery times to any urban place in the UK and any country in the world.

Features 462

HENGSTLER's H-462 safety relay provides absolute reliability, sturdy construction and a long electric life-time. As a result, these safety relays can be used wherever high availability is essential, even at high switching loads. The drive system can be supplied as a monostable version either for DC or AC. In addition, the H-462 relay is available as a DC bistable version. For special applications, it is possible to quote solutions in which the load current is fed direct to the relay coil, which enables the correct functioning of the load to be monitored. H-462 safety relays conform to EN 50205 standard, Application type A, and IEC EN 61810-1. In addition, these safety relays also meet the requirements for railway signal relays in accordance with UIC 736e.
  • 4 or 6 contacts
  • max. 10 A switching and constant current
  • Drive available as DC monostable, DC bistable, AC monostable and as load-current controlled
  • Ambient temperatures -25 to +80 °C
  • Forcibly guided contacts to EN 50205, Application type A
  • Meets requirements for signal relays under UIC 736e
  • cULus and TUV approvals
Function / ApplicationSafety relay
Product lineHENGSTLER
Relay family462
Contactsetforcibly guided
According EN 50205Application type A
Ambient temperature [°C]-25 ... +80 °C
Soldering heat resistance [°C]260 °C
Max. soldering time [s]5 s
Pins pre-soldered with Sn 100
Approval
  • TUV
  • cULus
Standards
  • EN 50205
  • IEC 61810-1
  • UL 508
Meets the requirements
  • RoHS
  • UIC 736
Number of NO contacts2 ... 4
Number of NC contacts1 ... 3
Number of CO contacts0
Size1 / 2
Dimensions L x W x H [mm]
  • Size 1: 57,8 x 20,5 x 48,6 mm
  • Size 2: 67,4 x 20,5 x 48,6 mm
Housingdustproof (RT II)
Shock resistance NO / NC [g]10/10 g
Puls duration (half sinus)16 ms
Vibration resistance NO / NC [g]10/10 g
Frequency range [Hz]10 - 55 Hz
Operating time NC contact, contact opens [ms] 17 ms
Operating time NO contact, contact closes [ms] 23 ms
Releasing time NO contact, contact opens [ms] 5 ms
Releasing time NC contact, contact closes [ms] 7 ms
Mechanical service life (without load)10,000,000 switching cycles
Connection type
  • Solder pins for pcb
  • Coil: Wire
Fixing typeContact: Solder pins
Drive system
  • DC monostable
  • AC monostable
  • DC bistable
  • DC load current activation
Nominal coil voltage [V]
  • DC/AC monostable
  • DC bistable/loadcurrent
Nominal coil current [A]5 ... 230 V
Resistance tolerance [%]10 ... 73,700 Ohm
Max. switching current [A]
  • AgCdO + 0,2 ... 10 µm Au
  • AgSnO + 0,2 ... 5 µm Au
Continuous current Ith2 at same time over 2 contacts [A] 10 A
Max. switching capacity [VA]230/240 V
Max. switching capacity [W]2000 VA
Switching capacity DC-13 at 24 V [Ie in A]4 A
Contact gap about open contact2 A
Short-circuit capacity 1000 A / AC 230 V [A]100,000 cycles
Insulation10 A
Function / ApplicationSafety relay
Product lineHENGSTLER
Relay family462
Contactsetforcibly guided
According EN 50205Application type A
Ambient temperature [°C]-25 ... +80 °C
Soldering heat resistance [°C]260 °C
Max. soldering time [s]5 s
Pins pre-soldered with Sn 100
Approval
  • TUV
  • cULus
Standards
  • EN 50205
  • IEC 61810-1
  • UL 508
Meets the requirements
  • RoHS
  • UIC 736
Number of NO contacts2 ... 4
Number of NC contacts1 ... 3
Number of CO contacts0
Size1 / 2
Dimensions L x W x H [mm]
  • Size 1: 57,8 x 20,5 x 48,6 mm
  • Size 2: 67,4 x 20,5 x 48,6 mm
Housingdustproof (RT II)
Shock resistance NO / NC [g]10/10 g
Puls duration (half sinus)16 ms
Vibration resistance NO / NC [g]10/10 g
Frequency range [Hz]10 - 55 Hz
Operating time NC contact, contact opens [ms] 17 ms
Operating time NO contact, contact closes [ms] 23 ms
Releasing time NO contact, contact opens [ms] 5 ms
Releasing time NC contact, contact closes [ms] 7 ms
Mechanical service life (without load)10,000,000 switching cycles
Connection type
  • Solder pins for pcb
  • Coil: Wire
Fixing typeContact: Solder pins
Drive system
  • DC monostable
  • AC monostable
  • DC bistable
  • DC load current activation
Nominal coil voltage [V]
  • DC/AC monostable
  • DC bistable/loadcurrent
Nominal coil current [A]5 ... 230 V
Resistance tolerance [%]10 ... 73,700 Ohm
Max. switching current [A]
  • AgCdO + 0,2 ... 10 µm Au
  • AgSnO + 0,2 ... 5 µm Au
Continuous current Ith2 at same time over 2 contacts [A] 10 A
Max. switching capacity [VA]230/240 V
Max. switching capacity [W]2000 VA
Switching capacity DC-13 at 24 V [Ie in A]4 A
Contact gap about open contact2 A
Short-circuit capacity 1000 A / AC 230 V [A]100,000 cycles
Insulation10 A