We are not the manufacturer, authorised distributor or authorised representative of the Wenglor brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to get Wenglor OY1P303P0102, in addition order other industrial equipment and spare parts for its fix, please call FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Oman, Sudan, Lebanon, Argentina, Moldova, Austria, South Sudan, The Gambia, Togo, South Korea, Côte d\'Ivoire, Peru, Djibouti, Uzbekistan, Papua New Guinea, Libya, Uganda, Luxembourg, Switzerland, Nigeria, Saudi Arabia, Dominica, Liberia, Niger, Bahrain, Laos, Hungary, Israel, Mauritius, Cyprus, Paraguay, Palestine, Barbados, Kenya, Honduras, India, Azerbaijan, Estonia, Bhutan, Egypt, Ghana, Swaziland, Madagascar, Burkina Faso.
We have been delivering Wenglor goods all around the United Kingdom and anywhere in the world for over 9 years. All apparatus and components are provided with appropriate quality certificates, along with a guarantee from the official producer of products Wenglor.
Thanks to the direct deliveries from global European manufacturers and a nominal trade margin, we propose our customers the most affordable prices for all products displayed in our catalogue. If necessary, our professional managers will help you select industrial instruments that will fully meet the concerns of the mode of operation. More than 4,000 consumers have already appreciated the high quality of the goods we transport and the dedication of the FAMAGA employees.
To clarify the charge of Wenglor OY1P303P0102 and delivery terms, you can fill out a special filling form on our website, dispatch a list of required instruments by E-mail or call to the mentioned phone numbers. We will be able to make the best financial offer for you and give optimal delivery times to any urban place in the United Kingdom and any country in the world.
Working Range | 50...3050 mm |
Measuring Range | 3000 mm |
Reproducibility maximum | 1 mm |
Linearity Deviation (200...3050 mm) | 7 mm |
Linearity Deviation (50...200 mm) | 15 mm |
Switching Hysteresis | 3...20 mm |
Light Source | Laser (red) |
Wavelength | 660 nm |
Service Life (T = +25 °C) | 100000 h |
Laser Class (EN 60825-1) | 1 |
Max. Ambient Light | 10000 Lux |
Beam Divergence | < 2 mrad |
Supply Voltage | 18...30 V DC |
Current Consumption (Ub = 24 V) | < 70 mA |
Switching Frequency | 250 Hz |
Measuring Rate | 1...500 /s |
On-/Off-Delay | 0...10000 ms |
Temperature Drift | < 0,4 mm/K |
Temperature Range | -40...50 °C |
Number of Switching Outputs | 2 |
Switching Output Voltage Drop | < 2,5 V |
Switching Output/Switching Current | 100 mA |
Analog Output | 0...10 V/4...20 mA |
Short Circuit Protection | yes |
Reverse Polarity and Overload Protection | yes |
Teach Mode | HT, VT, FT, TP |
Interface | IO-Link V1.1 |
Protection Class | III |
Setting Method | Menu (OLED) |
Housing Material | Plastic |
Optic Cover | PMMA |
Degree of Protection | IP68 |
Connection | M12 ? 1, 4-pin |
MTTFd (EN ISO 13849-1) | 349,73 a |
Error Output | yes |
Contamination Output | yes |
Configurable as PNP/NPN/Push-Pull | yes |
Analog Output | yes |
IO-Link | yes |