Name
AZ 16-12ZVRK-M16
Part number
101154221
Category
Switches
Type
Cylindrical safety Switch
Description
Safety switch
Stock availability:
10 In stock
If you want to purchase Schmersal AZ 16-12ZVRK-M16 101154221, along with require other industrial equipment and constituent parts for its restore, please connect FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Slovakia, Moldova, Guyana, Myanmar, Iraq, Haiti, San Marino, Rwanda, Belarus, Namibia, Sierra Leone, Togo, China, Andorra, Mauritius, Morocco, Tonga, Lithuania, Hungary, Liberia, Côte d\'Ivoire, South Sudan, Angola, Lesotho, Bhutan, Antigua and Barbuda, Bosnia and Herzegovina, Sudan, Sweden, El Salvador, Panama, Yemen, Swaziland, Niger, Denmark, Norway, Slovenia, Lebanon, Egypt, Turkey, Grenada.
We have been distributing Schmersal goods all around Great Britain and anywhere in the globe for over 11 years. All instruments and constituents are provided with appropriate quality certificates, along with a guarantee from the official creator of products Schmersal.
Thanks to the prompt supplies from prominent European manufacturers and a minimal trade margin, we give our customers the most reasonable prices for all products displayed in our catalogue. If necessary, our professional managers will help you choose industrial instruments that will fully meet the necessities of the mode of operation. More than 4,000 customers have already praised the high quality of the goods we deliver and the proficiency of the FAMAGA staff.
To clear up the value of Schmersal AZ 16-12ZVRK-M16 101154221 and shipment time, you can fill out a special inquiry form on our website, dispatch a list of essential instruments by E-mail or call to the quoted phone numbers. We will be able to compose the best commercial offer for you and prepare short supply times to any urban place in the United Kingdom and any country in the earth.
General data | |
Standards | EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-1 |
Coding level according to EN ISO 14119 | Low |
Working principle | electromechanical |
Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
General data - Features | |
Number of actuating directions | 3 |
Number of auxiliary contacts | 1 |
Number of safety contacts | 2 |
Number of cable glands | 3 |
Safety classification | |
Standards | EN ISO 13849-1 |
Performance Level, up to | c |
Category | 1 |
B10D Normally-closed contact (NC) | 2,000,000 Operations |
Note | Electrical life on request. |
B10D Normally-open contact (NO) | 1,000,000 Operations |
Note | at 10% Ie and ohmic load |
Mission time | 20 Year(s) |
Safety classification - Fault exclusion | |
Please note: | Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. |
Performance Level, up to | d |
Category | 3 |
Note | for 2-channel use and with suitable logic unit. |
Mission time | 20 Year(s) |
Mechanical data | |
Mechanical life, minimum | 1,000,000 Operations |
Latching force | 30 N |
Positive break travel | 8 mm |
Positive break force per NC contact, minimum | 10 N |
Positive break force, minimum | 20 N |
Actuating speed, maximum | 2 m/s |
Mounting | Screws |
Type of the fixing screws | 2x M6 |
Mechanical data - Connection technique | |
Cable entry | 3 x M16 x 1,5 |
Termination | Screw terminals |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 2.5 mm² |
Note (Cable section) | All indications including the conductor ferrules. |
Allowed type of cable | solid single-wire solid multi-wire flexible |
Ambient conditions | |
Degree of protection | IP67 |
Ambient temperature | -30 ... +80 °C |
Storage and transport temperature, minimum | -40 °C |
Storage and transport temperature, maximum | +85 °C |
Permissible installation altitude above sea level, maximum | 2,000 m |
Ambient conditions - Insulation values | |
Rated insulation voltage Ui | 500 V |
Rated impulse withstand voltage Uimp | 6 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Electrical data | |
Thermal test current | 10 A |
Required rated short-circuit current | 1,000 A |
Switching element | NO contact, NC contact |
Switching principle | slow action, positive break NC contact |
Switching frequency | 4,000 /h |
Material of the contacts, electrical | Silver |
Electrical data - Safety contacts | |
Voltage, Utilisation category AC-15 | 230 VAC |
Current, Utilisation category AC-15 | 4 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 4 A |
Electrical data - Auxiliary contacts | |
Voltage, Utilisation category AC-15 | 230 VAC |
Current, Utilisation category AC-15 | 4 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 4 A |