We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NJ8-18GK-N-150
Part number
106466
Type
Inductive sensor
Description
Inductive sensor NJ8-18GK-N-150
Stock availability:
On request
If you want to get Pepperl+Fuchs NJ8-18GK-N-150 106466, along with order other industrial equipment and replacement parts for its refit, please approach FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Cameroon, Bahrain, Zimbabwe, Qatar, Montenegro, Costa Rica, Oman, Jamaica, Slovenia, Chad, Georgia, Djibouti, Mozambique, Liberia, Iran, Palestine, Turkey, Guatemala, Eswatini, Estonia, Argentina, Suriname, Honduras, Cape Verde, Belarus, Greece, Spain, Switzerland, Niger, Albania, El Salvador, Dominican Republic, Denmark, Angola, Côte d\'Ivoire, Kenya, Vietnam, Myanmar, Iraq, The Gambia, India, Serbia, Burkina Faso, Brunei.
We have been supplying Pepperl+Fuchs products all over the United Kingdom and anywhere in the globe for over 9 years. All equipment and parts are provided with appropriate quality certificates, along with a guarantee from the official producer of products Pepperl+Fuchs.
Thanks to the upfront deliveries from leading European manufacturers and a minimal trade margin, we recommend our customers the most fair costs for all products exhibited in our catalogue. If necessary, our qualified specialists will help you pick industrial instruments that will fully meet the necessities of the mode of operation. More than 4,000 customers have already comprehended the high quality of the units we bring and the competence of the FAMAGA employees.
To clear up the value of Pepperl+Fuchs NJ8-18GK-N-150 106466 and delivery terms, you can fill in a special inquiry form on our website, give a list of essential machinery by E-mail or call to the quoted phone numbers. We will be able to make the best sales offer for you and prepare prompt distribution times to any urban place in Great Britain and any country in the globe.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 8 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 6.48 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega,) | |
Switching frequency | 0 ... 200 Hz | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le, 1 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
EAC conformity | TR CU 012/2011 | |
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0452 | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -40 ... 150 °C (-40 ... 302 °F) | |
Mechanical specifications | ||
Connection type | cable SIHF , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | PPS | |
Sensing face | PPS | |
Degree of protection | IP65 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ8-18GK-N-150... | |
Effective internal capacitance | max. 70 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ8-18GK-N-150... | |
Effective internal capacitance | max. 70 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ8-18GK-N-150... | |
Effective internal capacitance | max. 70 µ,F A cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H A cable length of 10 m is considered. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G |