Specifications FS-V21RP

If you want to buy Keyence FS-V21RP , as well as require other industrial equipment and spare parts for its refit, please approach FAMAGA .

We have been supplying Keyence products throughout the UK and anywhere in the earth for over 10 years. All equipment and materials are provided with appropriate quality certificates, together with a guarantee from the official manufacturer of products Keyence.

Thanks to the upfront deliveries from leading European manufacturers and a low trade margin, we give our customers the most fair costs for all products presented in our catalogue. If necessary, our professional managers will help you select industrial apparatus that will fully meet the requirements of the production process. More than 4,000 buyers have already appreciated the high quality of the products we bring and the professionalism of the FAMAGA staff.

To clear up the expense of Keyence FS-V21RP and delivery times, you can fill out a special inquiry form on our website, give a list of necessary equipment by E-mail or call to the specified phone numbers. We will be able to make the best commercial offer for you and present optimal supply times to any city in Great Britain and any country in the world.

Features FS-V21RP

Fibre Amplifier, Cable Type, Main Unit, PNP
Model FS-V21RP
Type Main unit, PNP
Light source Red LED
Response time 250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER TURBO) /4 ms (ULTRA TURBO) /500 µs (HIGH RESOLUTION) /50 µs (HIGH SPEED)
Output selection Light-ON/Dark-ON selectable
Indicator lamp Operation indicator: Red LED Dual digital monitor: Dual 7-segment display [Preset Value (4-digit green LED indicator) and Current Value (4-digit red LED indicator) illuminated together. Current Value range: 0 to 65,520, Excess gain: 0 P to 999 P] Hold function: Possible to display both peak and bottom hold values. Bar LED monitor: Possible to display together with Current Value Excess gain displayed (85 to 115 % in 7 steps)
Detection mode Light intensity/rising edge/falling edge
Shift function Max. ±1,999 (variable)
Timer function Mode Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, selectable
Variable range 1 to 500 ms [1 to 30 ms (in 1 ms increments), 30 to 50 ms (in 2 ms increments), 50 to 200 ms (in 10 ms increments), 200 to 500 ms (in 50 ms increments)]
Accuracy ±10 % of the Preset Value
Control output PNP open-collector 100 mA max. (30 VDC max.)*1, Residual voltage: 1 V max.
Rating Power voltage 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less
Power consumption Normal S-APC OFF: 650 mW max. (27 mA max. at 24 VDC), S-APC ON: 720 mW max. (30 mA max. at 24 VDC)*2
ECO half S-APC OFF: 530 mW max. (22 mA max. at 24 VDC), S-APC ON: 600 mW max. (25 mA max. at 24 VDC)*2
ECO all S-APC OFF: 480 mW max. (20 mA max. at 24 VDC), S-APC ON: 550 mW max. (23 mA max. at 24 VDC)*2
Environmental resistance Ambient light Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max.
Ambient temperature -10 to +55 °C (No freezing)*3
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 500 m/s2, 3 times in each of the X, Y, and Z directions
Case material Polycarbonate
Weight Approx. 80 g (including 2-m cable)
*1 20 mA at maximum for the expansion unit. *2 S-APC will be always turned ON when the high-resolution or high-speed mode is selected. S-APC is by default set to OFF in any other mode. *3 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less. 3 to 10 Units: –10 to +50 °C 11 to 16 Units: –10 to +45 °C