Mounting bracket LR-TB5000CL Keyence
Mounting bracket LR-TB5000CL Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.

Keyence LR-TB5000CL

Manufacturer

Keyence

Country

Japan

Name

LR-TB5000CL

Type

Mounting bracket

Description

Scanner Head Bracket

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications LR-TB5000CL

If you want to get Keyence LR-TB5000CL , additionally demand other industrial equipment and constituent parts for its fix, please approach FAMAGA .

We have been supplying Keyence items all over the United Kingdom and anywhere in the world for over 9 years. All equipment and constituents are provided with appropriate quality certificates, with a guarantee from the official creator of products Keyence.

Thanks to the shortest shipment from prominent European manufacturers and a minimal trade margin, we offer our customers the most fair costs for all products exhibited in our catalogue. If necessary, our qualified specialists will help you select industrial instruments that will fully meet the requirements of the mode of operation. More than 4,000 customers have already comprehended the high quality of the units we bring and the dedication of the FAMAGA workers.

To clear up the cost of Keyence LR-TB5000CL and shipment time, you can complete a special order form on our website, give a list of essential equipment by E-mail or call to the quoted phone numbers. We will be able to make the best sales offer for you and give prompt shipment times to any city in Great Britain and any country in the globe.

Features LR-TB5000CL

Detection distance 5 m, Cable with connector M12, Laser Class 1
Model LR-TB5000CL
Type Cable with connector M12
Detectable distance 60 to 5000 mm*1
Spot diameter Variable (use a spot diameter of 40 mm or less)
Response time 2 ms/20 ms/50 ms/200 ms/2000 ms selectable
Light source Type Red laser (660 nm)
Laser class Class 1 laser product (IEC60825-1,FDA (CDRH) Part1040.10*2)
Mutual interference prevention function 4 units (when using the interference prevention function)
Timer OFF/OFF delay/ON delay/One-shot
Power voltage 20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS
Current consumption 50 mA or less (without load)*3
I/O Control output NPN open collector/PNP open collector selectable 30 VDC or less, 50 mA or less, residual voltage: 2 V or less, N.O./N.C. selectable *4*5
External input Switchable between transmission OFF, teaching, and reference surface update Short-circuit current: 1 mA or less for both NPN and PNP For the applied voltage, see the wiring diagrams (pages 2 and 3 in the instruction manual). For the input times, see the time charts (page 4 in the instruction manual).*3
Analogue output Current output/Voltage output selectable Current output: 4 to 20 mA with a max. load resistance of 500 ? Voltage output: 0 to 10 V with an external load resistance of 5 k? or more *4*5
Protection circuit Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge
Environmental resistance Enclosure rating IP65/IP67 (IEC60529)
Ambient light Incandescent lamp/Sunlight: 10,0000 lux or less
Ambient temperature -20 to +55 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 1,000 m/s2, 6 times in each of the X, Y, and Z directions
Material Case: Zinc die cast (Nickel chrome plating), Indicator cover and buttons: PES, Lens cover and display: PMMA (scratch-resistant coating specifications), Cable bushing: PBT, Cable: PVC, M12 connector: TPE, PBT, Nickel-plated brass
Accompanying items Instruction manual
Weight Approx. 160 g
*1 The range for displayable distance is from 50 to 5200. *2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *3 150 mA or less (with load) *4 You can select the I/O from the following combinations. Control output ? 2, control output + external input Control output + analogue output (LR-TB5000/TB5000C/TB5000CL only), External input + analogue output (LR-TB5000/TB5000C/TB5000CL only) (For details on the setting method, see the instruction manual.) *5 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com). If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.