If you want to purchase IFM O1D155, in addition request other industrial equipment and spare parts for its adjust, please connect FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Croatia, Egypt, Montenegro, Ghana, Iran, Bulgaria, Eritrea, The Bahamas, Kiribati, Angola, Mauritania, Philippines, Papua New Guinea, Sri Lanka, Dominica, Venezuela, Liechtenstein, Costa Rica, Guinea, Guinea-Bissau, Guyana, Israel, Côte d\'Ivoire, Ecuador, Burkina Faso, Central African Republic, Armenia, Liberia, Niger, Libya, Nicaragua, Sweden, Spain, Finland, Luxembourg, South Sudan, Barbados, Indonesia, Peru, Albania, Cyprus.
We have been distributing IFM products throughout the United Kingdom and anywhere in the planet for over 10 years. All machinery and materials are provided with appropriate quality certificates, along with a guarantee from the official creator of products IFM.
Thanks to the prompt supplies from major European manufacturers and a low trade margin, we suggest our customers the most fair costs for all products displayed in our catalogue. If necessary, our professional managers will help you elect industrial instruments that will fully meet the needs of the operation procedure. More than 4,000 customers have already comprehended the high quality of the items we deliver and the dedication of the FAMAGA staff.
To define the charge of IFM O1D155 and delivery times, you can fill in a special inquiry form on our website, give a list of desirable instruments by E-mail or call to the indicated phone numbers. We will be able to create the best commercial offer for you and present short supply times to any urban place in the United Kingdom and any country in the globe.
Electronic data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Voltage [V] | 18... 30 DC | ||||||||||
Current consumption [mA] | <150 | ||||||||||
Protection class | III | ||||||||||
Power protection | da | ||||||||||
Type of light | red light | ||||||||||
Wavelength [nm] | 650 | ||||||||||
Stand. lifetime [h] | 50000 | ||||||||||
Inputs/outputs | |||||||||||
Number of inputs and outputs | Number of digital outputs: 2, Number of analog outputs: 1 | ||||||||||
Outputs | |||||||||||
Total number of outputs | 2 | ||||||||||
Electrical version | PNP | ||||||||||
Number of digital outputs | 2 | ||||||||||
Output function | normally open / normally closed, (programmable) | ||||||||||
Max. allowable current load per output [mA] | 200 | ||||||||||
Number of analog outputs | 1 | ||||||||||
Current analog output [mA] | 4...20, (IEC 61131-2) | ||||||||||
Sub. load [?] | 250 | ||||||||||
Voltage analog output [V] | 0...10, (IEC 61131-2) | ||||||||||
Min. load resistance [?] | 5000 | ||||||||||
Short-circuit protection | yes | ||||||||||
Short-circuit protection type | total | ||||||||||
Power overcurrent protection | yes | ||||||||||
Max. light Spot width [mm] | 8 | ||||||||||
Max. height of the light spot [mm] | 8 | ||||||||||
Dimension of the light spot in relation to | 6 m | ||||||||||
Background suppression [m] | 6...100 | ||||||||||
Measuring/setting range | |||||||||||
Measuring range [m] | 0.3... 6, (white paper 200 x 200 mm) | ||||||||||
Sampling Rate [Hz] | 1...33 | ||||||||||
Interfaces | |||||||||||
Communication Interface | IO-Link | ||||||||||
The transmission method | COM2 (38.4 kBaud) | ||||||||||
IO-Link Check | 1. 1 | ||||||||||
SDCI standard | IEC 61131-9 | ||||||||||
IO-Link device ID | 812 d / 00 03 2 Ch | ||||||||||
Profiles | Smart Sensor: Sensor Identification, Binary Data Channel, Process Value, Sensor Diagnosis | ||||||||||
SIO mode | yes | ||||||||||
Port type desired | A | ||||||||||
Analog operating data | 2 | ||||||||||
Binary operating data | 2 | ||||||||||
minimal [ms] | 6 | ||||||||||
Operating conditions | |||||||||||
Environmental temperature [°C] | -10... 60 | ||||||||||
Protection degree | IP 67 | ||||||||||
Tests / Approvals | |||||||||||
EMS |
EN 60947-5- 2 |
Attention: | laser |
laser class: | 1 | EN / IEC60825-1:2007 |
EN / IEC60825-1:2014 | |
Complies with regulation 21 CFR 1040, except for deviations described in Laser Notice No. 50, which is dated July 2007. |
Status output | 2 x LED, yellow |
operating mode | LED, green |
range, programming | letter-digital display, 4-digit |
Shield cover, E21133 |
Power supply voltage "supply class 2" according to cULus | |
Packing value | 1 pc. |
electrical connection | |
---|---|
Connection | Socket: 1 x M12 |