We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to get Euchner 121062, along with request other industrial equipment and spare parts for its refit, please approach FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Croatia, Lesotho, Greece, Gambia, Saudi Arabia, Tanzania, Belize, Spain, Cape Verde, Panama, Jamaica, Mauritania, Luxembourg, Mozambique, Serbia, Qatar, Togo, Myanmar, Suriname, Mali, Burundi, South Africa, Tunisia, Congo, Brunei, Sri Lanka, Indonesia, Norway, Burkina Faso, Algeria, Vietnam, Denmark, Guyana, Swaziland, Libya, The Gambia, Japan, Albania, India, The Bahamas, Grenada, New Zealand, Yemen, Kiribati, Egypt.
We have been supplying Euchner items throughout the United Kingdom and anywhere in the globe for over 9 years. All instruments and components are provided with appropriate quality certificates, along with a guarantee from the official manufacturer of products Euchner.
Thanks to the upfront deliveries from key European manufacturers and a minimal trade margin, we give our customers the most fair costs for all products exhibited in our catalogue. If necessary, our professional managers will help you pick industrial instruments that will fully meet the necessities of the mode of operation. More than 4,000 consumers have already comprehended the high quality of the items we bring and the competence of the FAMAGA staff.
To clear up the charge of Euchner 121062 and delivery times, you can fill in a special inquiry form on our website, send a list of essential machinery by E-mail or call to the quoted phone numbers. We will be able to create the best sales offer for you and prepare prompt distribution times to any urban place in Great Britain and any country in the globe.
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted into the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics, there is a fault |
S2 | One NO contact, illuminated |
S3 | One NO contact, illuminated |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0,25 Hz |
Connection | Cable entries M20x1.5 |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connection cross-section | |
(Rigid/flexible) | 0,13 ... 1,5 mm? (AWG 24 ... AWG 16) |
(Rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0,25 ... 1,5 mm? |
(Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0,25 ... 0,75 mm? |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Additional feature | Incl. cover set ID. No. 120344 |
Product version number | V3.0.3 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Mission time | 20 y |
Housing material | Die-cast zinc/stainless steel powder-coated |
Weight | |
Net | 0,75 kg |
Ambient temperature | -20 ... 55 °C |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Product version number | V2.0.0 |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN right |
Product version number | V3.0.0 |