We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand in Great Britain. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CET3-AR-CRA-AH-50F-SG-113965
Part number
113965
Description
Burg
Stock availability:
On request
If you want to purchase Euchner CET3-AR-CRA-AH-50F-SG-113965 113965, along with request other industrial equipment and spare parts for its fix, please connect FAMAGA United Kingdom, United States, Netherlands, Germany, France, Ireland, Malawi, Fiji, Chad, South Korea, Belgium, Switzerland, Senegal, Qatar, Belize, Antigua and Barbuda, Sri Lanka, Equatorial Guinea, Benin, Tanzania, Bahamas, Russia, Brunei, Burundi, Finland, East Timor, Japan, Tajikistan, Greece, Argentina, Belarus, Bosnia and Herzegovina, Laos, Tunisia, Ukraine, Sudan, Côte d\'Ivoire, Bangladesh, Turkey, Panama, Cuba, Azerbaijan, Namibia, Cameroon, New Zealand, Mauritius.
We have been distributing Euchner goods throughout Britain and anywhere in the planet for over 9 years. All instruments and constituents are provided with appropriate quality certificates, along with a guarantee from the official manufacturer of products Euchner.
Thanks to the prompt supplies from global European manufacturers and a low trade margin, we suggest our customers the most reasonable prices for all products exposed in our catalogue. If necessary, our professional managers will help you choose industrial instruments that will fully meet the necessities of the operation procedure. More than 4,000 buyers have already praised the high quality of the goods we deliver and the competence of the FAMAGA staff.
To illuminate the price of Euchner CET3-AR-CRA-AH-50F-SG-113965 113965 and delivery terms, you can complete a special order form on our website, send a list of desirable instruments by E-mail or call to the indicated phone numbers. We will be able to create the best sales offer for you and prepare adequate supply times to any place in the United Kingdom and any country in the earth.
CET3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | illuminates when door is closed |
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output (semiconductor) |
RST | Reset input |
J | Teach-in input |
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Z | ±4 mm |
Y | ±5 mm |
X | ±5 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED | 24 V DC -15% ... 10% |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
External (operating voltage UB) | 0,25 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Low U(OA) / U(OB) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.400 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Teach-in input | |
Input voltage | |
High | 15 ... 27,6 V DC |
Low | 0 ... 1 V DC |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head downward or horizontal | 3.1 x 10-9 |
Head upward | 4.29 x 10-8 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |