Euchner CES-A-C5H-01 091458

Manufacturer

Euchner

Country

Germany

Name

CES-A-C5H-01

Part number

091458

Description

SICHERHEITSSCHALTER UNICODE CES-A-C5H-01

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CES-A-C5H-01 091458

If you want to buy Euchner CES-A-C5H-01 091458, in addition order other industrial equipment and constituent parts for its fix, please contact FAMAGA .

We have been distributing Euchner units all around the United Kingdom and anywhere in the world for over 10 years. All equipment and materials are provided with appropriate quality certificates, along with a guarantee from the official manufacturer of products Euchner.

Thanks to the prompt supplies from prominent European manufacturers and a low trade margin, we recommend our customers the most affordable prices for all products displayed in our catalogue. If necessary, our qualified specialists will help you choose industrial instruments that will fully meet the requirements of the operation procedure. More than 4,000 customers have already praised the high quality of the units we supply and the proficiency of the FAMAGA employees.

To define the value of Euchner CES-A-C5H-01 091458 and delivery times, you can fill out a special inquiry form on our website, dispatch a list of essential equipment by E-mail or call to the indicated phone numbers. We will be able to make the best trade offer for you and prepare optimal supply times to any urban place in the United Kingdom and any country in the globe.

Features CES-A-C5H-01 091458

  • Safety switch with integrated evaluation electronics
  • Possible to switch pulsed signals
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Unicode
Approach directionCan be adjusted in 90° steps Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught in. Category according to EN ISO 13849-1Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN ISO 13849-1
LED indicator
STATEStatus LED
OUT/ERRORSafety outputs status / diagnostics LED (combined)
Additional connection
OUTMonitoring output (semiconductor)
Attention:The operating distance may vary depending on the background material and installation situation. (Only in combination with actuator CES-A-BBA, CES-A-BCA) Typical operating distance For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the operating distance of the side lobes is not entered. (Only in combination with actuator CES-A-BPA) Typical operating distance For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the operating distance of the side lobes is not entered.
Dimensions According to EN 60947-5-2: (LxWxH) 131x40x40
Housing material Plastic, PBT
Weight
Net 0,4 kg
Ambient temperature
At UB = 24 V DC -20 ... 55 °C
Degree of protection IP67
Mounting distance
Between 2 read heads or 2 actuators min.80 mm
Installation orientation Any
Tightening torque
Screws fastening bracket read head max.0,6 Nm
Fixing screws housing max.1 Nm
Ready delay max.3 s
Reaction time
After change in the actuation status max.180 ms
Switching frequency max.1 Hz
Dwell time min.0,5 s
Connection M12 plug connector, 8-pin, screen can be applied
Electrical connection ratings
Operating voltage DC 18 ... 24 ... 27 V DC Regulated, residual ripple < 5 %
Current consumption 80 mA
Fusing
(External) operating voltage 0,25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Safety outputs LA / LB
Type of output Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled
Output voltage
HIGH U(LA) U(+LA) - 1,5 ... U(+LA) V DC
HIGH U(LB) U(+LB) - 1,5 ... U(+LB) V DC
LOW U(LA) / U(LB) 0 ... 1 V DC
Output current
per safety output 1 ... 400 mA
Fusing
External, safety circuit U(+LA) / U(+LB) 0.4 A medium slow-blow
Utilization category according to EN 60947-5-2
DC-13 24V 400mA
Switching load
According to UL max. DC 24 V, class 2
Rated conditional short-circuit current max.100 A
Discrepancy time
(Between the operating points of both safety outputs) max.120 ms
Power supply output load
U(+LA) / U(+LB) 24 V DC 18 ... 27 V DC
Monitoring output OUT
Type of output Semiconductor output, p-switching, short circuit-proof
Output voltage 0,8 x UB ... UB V DC
Output current max.20 mA
STATE LED
LED indicator Status - LED
LED OUT / ERROR
LED indicator Safety outputs status / diagnostics (combined)
Work area
Repeat accuracy R max.10 %
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 3.7 x 10-9
Diagnostic Coverage (DC) 99 %
Mission time 20 y
In combination with Actuator CES-A-BPAOperating distance
Distance s, actuator
Minimum distance for side approach direction min.6 mm
Switch-on distance
With center offset m=0 22 mm
Assured switch-off distance Sar max.58 mm
Assured operating distance Sao
With center offset m=0 min.15 mm
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BDA-20Operating distance
Distance s, actuator
Minimum distance for side approach direction min.5 mm
Switch-on distance
With center offset m=0 21 mm
Assured switch-off distance Sar max.41 mm
Assured operating distance Sao
With center offset m=0 min.19 mm
Switching hysteresis min.2 mm
In combination with Actuator CES-A-BBA, CES-A-BCAOperating distance
Distance s, actuator
Minimum distance for side approach direction min.4 mm
Switch-on distance
With center offset m=0 20 mm
Assured switch-off distance Sar max.40 mm
Assured operating distance Sao
With center offset m=0 min.18 mm
Switching hysteresis min.2 mm